一、日常巡檢內(nèi)容及標(biāo)準(zhǔn)如下:
1、開(kāi)關(guān)柜(開(kāi)關(guān)柜配電柜 )外觀檢查。聊城ggd低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜GGD )hege
標(biāo)準(zhǔn):開(kāi)關(guān)柜(源創(chuàng)公司生產(chǎn)的開(kāi)關(guān)柜 )外殼無(wú)變形,聊城ggd低壓開(kāi)關(guān)柜(源創(chuàng)工廠生成的開(kāi)關(guān)柜 )hege無(wú)損傷;防護(hù)油漆無(wú)嚴(yán)重銹蝕,聊城ggd低壓開(kāi)關(guān)柜(價(jià)格最優(yōu)的開(kāi)關(guān)柜 )國(guó)標(biāo)破損剝落;柜體安裝牢固,聊城ggd低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜哪家好 )插拔式外表清潔無(wú)雜物;開(kāi)關(guān)柜(鎧裝開(kāi)關(guān)柜 )的銘牌和標(biāo)識(shí)黏貼整齊,聊城ggd低壓開(kāi)關(guān)柜(配電開(kāi)關(guān)柜 )單元數(shù)無(wú)脫落。聊城ggd低壓開(kāi)關(guān)柜(雙層開(kāi)關(guān)柜 )國(guó)標(biāo)
2. 開(kāi)關(guān)柜(西門子35KV開(kāi)關(guān)柜 )運(yùn)行狀態(tài)參數(shù)檢查。聊城ggd低壓開(kāi)關(guān)柜(小型化開(kāi)關(guān)柜 )插拔式
標(biāo)準(zhǔn):儀器、儀表指示正常(與日常運(yùn)行值比較,聊城ggd低壓抽屜柜無(wú)差別或差別不大且與設(shè)備狀態(tài)相對(duì)應(yīng))。聊城ggd低壓開(kāi)關(guān)柜(直流開(kāi)關(guān)柜 )單元數(shù)
3.開(kāi)關(guān)柜(中低壓開(kāi)關(guān)柜 )相關(guān)器件、電氣接點(diǎn)及電線、電纜無(wú)超過(guò)規(guī)定溫度現(xiàn)象。聊城ggd低壓抽屜柜
標(biāo)準(zhǔn):用紅外測(cè)溫儀測(cè)量可見(jiàn)的相關(guān)器件、電氣接點(diǎn)、電線、電纜運(yùn)行溫度≤60℃,柜內(nèi)無(wú)異味。聊城gcs開(kāi)關(guān)柜(中置開(kāi)關(guān)柜 )
4. 開(kāi)關(guān)位置、指示燈指示、儀表顯示是否正確,聊城gcs開(kāi)關(guān)柜(繞線電機(jī)開(kāi)關(guān)柜 )各轉(zhuǎn)換開(kāi)關(guān)所處位置是否正常。聊城gck開(kāi)關(guān)柜(鼠籠電機(jī)開(kāi)關(guān)柜 )
標(biāo)準(zhǔn):開(kāi)關(guān)分合位置正確、無(wú)報(bào)警指示、轉(zhuǎn)換開(kāi)關(guān)在規(guī)定位置。聊城10kv高壓開(kāi)關(guān)柜(源創(chuàng)開(kāi)關(guān)柜 )型號(hào)
二、保養(yǎng)工作一年一次,聊城gck開(kāi)關(guān)柜(五防開(kāi)關(guān)柜 )內(nèi)容及標(biāo)準(zhǔn)如下:
1、柜體外殼檢查、清掃、排除日常巡視中發(fā)現(xiàn)的各種缺陷。聊城10kv高壓開(kāi)關(guān)柜(一體化開(kāi)關(guān)柜 )結(jié)構(gòu)
標(biāo)準(zhǔn):1)酒精、白棉布擦拭,聊城10kv高壓開(kāi)關(guān)柜(源創(chuàng)生產(chǎn)的開(kāi)關(guān)柜 )型號(hào)確保無(wú)積塵、無(wú)污漬;
2)防護(hù)油漆無(wú)嚴(yán)重銹蝕,聊城10kv高壓開(kāi)關(guān)柜(高低壓無(wú)線開(kāi)關(guān)柜 )結(jié)構(gòu)破損剝落,聊城10kv高壓開(kāi)關(guān)柜(可遠(yuǎn)程控制的開(kāi)關(guān)柜 )柜后放電否則進(jìn)行除銹、補(bǔ)漆。聊城10kv高壓開(kāi)關(guān)柜(山東開(kāi)關(guān)柜 )柜后放電
2、電纜室檢查、保養(yǎng)。聊城10kv高壓開(kāi)關(guān)柜(濰坊開(kāi)關(guān)柜 )故障
標(biāo)準(zhǔn):1)電纜孔密封完好;
2)電纜插頭固定螺釘無(wú)松動(dòng);
3)電纜標(biāo)識(shí)牌無(wú)脫落,聊城10kv高壓開(kāi)關(guān)柜(上海開(kāi)關(guān)柜 )故障電纜相序色標(biāo)沒(méi)有脫落;
4)電纜室干燥,聊城10kv高壓開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜 )設(shè)計(jì)沒(méi)有凝露情況,聊城10kv高壓開(kāi)關(guān)柜(高低壓開(kāi)關(guān)柜 )故障停電并清掃除塵。聊城10kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜 )設(shè)計(jì)
5)用酒精、白棉布擦拭絕緣子,聊城10kv高壓開(kāi)關(guān)柜(帶智能操控裝置開(kāi)關(guān)柜 )母線安裝方案確保無(wú)積塵、無(wú)污漬;
6)接地線無(wú)松動(dòng),聊城10kv高壓開(kāi)關(guān)柜(告知型號(hào)的開(kāi)關(guān)柜 )主母線多大連接牢固。聊城10kv高壓開(kāi)關(guān)柜(抽屜式開(kāi)關(guān)柜 )故障停電
3、接地刀閘開(kāi)關(guān)檢查。聊城10kv高壓開(kāi)關(guān)柜(35KV高壓開(kāi)關(guān)柜 )母線安裝方案
標(biāo)準(zhǔn):手動(dòng)操作接地刀閘開(kāi)關(guān)一個(gè)循環(huán),聊城10kv高壓開(kāi)關(guān)柜(10KV高壓開(kāi)關(guān)柜 )原理圖開(kāi)關(guān)動(dòng)作正常,聊城35kv高壓開(kāi)關(guān)柜(帶無(wú)線測(cè)溫開(kāi)關(guān)柜 )型號(hào)無(wú)卡滯,聊城35kv高壓開(kāi)關(guān)柜(介紹門鎖的開(kāi)關(guān)柜 )尺寸開(kāi)關(guān)位置與面板位置指示正常。聊城10kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜設(shè)計(jì) )主母線多大
4、斷路器室部件檢查、保養(yǎng)。聊城10kv高壓開(kāi)關(guān)柜(無(wú)線測(cè)溫裝置的開(kāi)關(guān)柜 )原理圖
標(biāo)準(zhǔn):1)將主斷路器搖至退出位,聊城35kv高壓開(kāi)關(guān)柜(24KV開(kāi)關(guān)柜 )的額定電壓是多少用小車將其拉至艙外,檢查一次回路隔離觸指及其聯(lián)接銅排是否有燒痕、放電的痕跡;視情況看是否需要使用砂紙打磨,聊城35kv高壓開(kāi)關(guān)柜(SF6開(kāi)關(guān)柜 )母線用酒精棉布擦拭;
2)在主斷路器隔離觸指均勻涂上0.5~1mm厚的導(dǎo)電膏;
3)按力矩要求緊固一次回路上各螺栓,聊城35kv高壓開(kāi)關(guān)柜(高低壓成套開(kāi)關(guān)柜 )多少錢緊固螺栓后檢查彈簧墊片應(yīng)平整,聊城35kv高壓開(kāi)關(guān)柜(低壓開(kāi)關(guān)柜 )結(jié)構(gòu)圖完成緊固操作后,聊城35kv高壓開(kāi)關(guān)柜(中壓開(kāi)關(guān)柜 )手車長(zhǎng)度給一次回路上各螺栓劃上防松線;
4)用酒精、白棉布擦拭斷路器室內(nèi)各部件,聊城35kv高壓開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜型號(hào) )系統(tǒng)圖確保無(wú)積塵、無(wú)污漬;
5)將主斷路器用小車推入斷路器室艙內(nèi)并搖至測(cè)試位,聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜配件 )說(shuō)明書(shū)手動(dòng)操作合分閘一個(gè)循環(huán),聊城開(kāi)關(guān)柜(開(kāi)關(guān)柜圖紙 )電氣原理圖詳解斷路器動(dòng)作正常,聊城配電柜和開(kāi)關(guān)柜(求購(gòu)高壓開(kāi)關(guān)柜 )的區(qū)別無(wú)卡滯,聊城高低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜測(cè)溫裝置 )基礎(chǔ)知識(shí)機(jī)械位置指示、斷路器分合位置指示、彈簧儲(chǔ)能與未儲(chǔ)能指示均正常。聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜五防 )型號(hào)
6)檢查無(wú)誤后,聊城開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜操作視頻 )設(shè)計(jì)規(guī)范搖至投入位,聊城環(huán)網(wǎng)柜和開(kāi)關(guān)柜(低壓開(kāi)關(guān)柜價(jià)格 )的區(qū)別按停送電要求執(zhí)行操作。聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜工作原理 )尺寸
5、二次回路室檢查、保養(yǎng)。聊城35kv高壓開(kāi)關(guān)柜(低壓開(kāi)關(guān)柜圖紙 )的額定電壓是多少
標(biāo)準(zhǔn):1)檢查二次接線:接線緊固,聊城高低壓開(kāi)關(guān)柜(高低壓開(kāi)關(guān)柜型號(hào) )廠家排名線號(hào)清晰;
2)檢查柜內(nèi)清潔:無(wú)積塵、無(wú)異物;
3)必要時(shí),聊城開(kāi)關(guān)柜(開(kāi)關(guān)柜母排測(cè)溫 )的五防是什么清掃除塵并緊固二次線。聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜用避雷器 )母線
三、一年一次的電氣試驗(yàn),聊城配電柜安裝口訣內(nèi)容及標(biāo)準(zhǔn)如下:
1、斷路器主回路絕緣試驗(yàn)。聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜無(wú)線測(cè)溫系統(tǒng) )多少錢
標(biāo)準(zhǔn):采用2500V兆歐表測(cè)量,聊城配電柜接線實(shí)物圖測(cè)量值大于50 MΩ。聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜的作用 )結(jié)構(gòu)圖
2、工頻交流耐壓試驗(yàn)(斷路器主回路對(duì)地、相間及斷口)。聊城35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜測(cè)溫裝置價(jià)格 )手車長(zhǎng)度
標(biāo)準(zhǔn):1)大修后:試驗(yàn)電壓值按規(guī)定值;
2)運(yùn)行中:試驗(yàn)電壓值按規(guī)定值的0.8倍。聊城35kv高壓開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜測(cè)溫 )系統(tǒng)圖
3、輔助回路和控制回路絕緣測(cè)試。聊城35kv高壓開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜價(jià)格 )說(shuō)明書(shū)
標(biāo)準(zhǔn):采用500V兆歐表測(cè)量,聊城380v低壓配電柜接線圖測(cè)量值大于2 MΩ。聊城開(kāi)關(guān)柜(開(kāi)關(guān)柜廠 )電氣原理圖詳解
四、必要時(shí)的故障檢修,聊城配電箱接線圖內(nèi)容及標(biāo)準(zhǔn)如下:
1、斷路器工作位置校正。聊城配電柜和開(kāi)關(guān)柜(SM6開(kāi)關(guān)柜 )的區(qū)別
標(biāo)準(zhǔn):用導(dǎo)電膠或凡士林涂于動(dòng)觸頭的內(nèi)圈,聊城低壓配電柜然后將手車推入至工作位置,聊城配電柜有輻射嗎再將其拉出,聊城配電柜生產(chǎn)廠家此時(shí)可用卡尺在靜觸頭上測(cè)量可見(jiàn)動(dòng)、靜觸頭的有效咬合深度應(yīng)為15~25mm。聊城高低壓開(kāi)關(guān)柜(電力開(kāi)關(guān)柜 )基礎(chǔ)知識(shí)
2、斷路器檢修和更換。聊城開(kāi)關(guān)柜(低壓開(kāi)關(guān)柜生產(chǎn) )設(shè)計(jì)規(guī)范
標(biāo)準(zhǔn):按照生產(chǎn)廠家的具體參數(shù)要求進(jìn)行更換。聊城環(huán)網(wǎng)柜和開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜生產(chǎn) )的區(qū)別
3、儀器、儀表檢修和更換。聊城高低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜測(cè)溫系統(tǒng) )廠家排名
標(biāo)準(zhǔn):按照生產(chǎn)廠家的具體參數(shù)要求進(jìn)行更換。聊城開(kāi)關(guān)柜(動(dòng)力開(kāi)關(guān)柜 )的五防是什么