手車(chē)柜體比一般電氣柜體大且重,濟(jì)南ggd低壓開(kāi)關(guān)柜(交流低壓開(kāi)關(guān)柜
)樣本重心較高易翻倒,濟(jì)南ggd低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜配電柜
)hege柜內(nèi)又是易損的電氣元件,濟(jì)南ggd低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜GGD
)國(guó)標(biāo)在搬運(yùn)時(shí)應(yīng)有防震、防潮、防雨等安全措施。濟(jì)南ggd低壓開(kāi)關(guān)柜(源創(chuàng)公司生產(chǎn)的開(kāi)關(guān)柜
)樣本為防止柜體變形和漆面受損,濟(jì)南ggd低壓開(kāi)關(guān)柜(源創(chuàng)工廠生成的開(kāi)關(guān)柜
)插拔式在搬運(yùn)時(shí)一般不要打開(kāi)包裝,濟(jì)南ggd低壓開(kāi)關(guān)柜(價(jià)格最優(yōu)的開(kāi)關(guān)柜
)單元數(shù)對(duì)特別易損的電氣元件,濟(jì)南ggd低壓抽屜柜分別包裝。濟(jì)南ggd低壓開(kāi)關(guān)柜(開(kāi)關(guān)柜哪家好
)hege
搬運(yùn)、吊裝手車(chē)柜通常使用的設(shè)備工具為汽車(chē)、汽車(chē)吊、電動(dòng)或手拉葫蘆以及利用施工現(xiàn)場(chǎng)建筑使用的起重機(jī)械等。濟(jì)南ggd低壓開(kāi)關(guān)柜(鎧裝開(kāi)關(guān)柜
)國(guó)標(biāo)起吊時(shí),濟(jì)南gcs開(kāi)關(guān)柜(配電開(kāi)關(guān)柜
)吊鉤應(yīng)在柜體重心垂直線上,濟(jì)南gck開(kāi)關(guān)柜(雙層開(kāi)關(guān)柜
)吊繩夾角應(yīng)小于45°,濟(jì)南10kv高壓開(kāi)關(guān)柜(西門(mén)子35KV開(kāi)關(guān)柜
)型號(hào)柜體直立,濟(jì)南10kv高壓開(kāi)關(guān)柜(小型化開(kāi)關(guān)柜
)結(jié)構(gòu)不得傾斜或倒立。濟(jì)南ggd低壓開(kāi)關(guān)柜(直流開(kāi)關(guān)柜
)插拔式對(duì)于目前使用的10KV高壓手車(chē)柜,濟(jì)南10kv高壓開(kāi)關(guān)柜(中低壓開(kāi)關(guān)柜
)柜后放電吊具一般選用8t汽車(chē)吊、3t以上葫蘆或使用施工現(xiàn)場(chǎng)提升機(jī)吊到配電室。濟(jì)南ggd低壓開(kāi)關(guān)柜(中置開(kāi)關(guān)柜
)單元數(shù)柜體就位時(shí),濟(jì)南10kv高壓開(kāi)關(guān)柜(繞線電機(jī)開(kāi)關(guān)柜
)故障配電室地坪面已完成,濟(jì)南10kv高壓開(kāi)關(guān)柜(鼠籠電機(jī)開(kāi)關(guān)柜
)設(shè)計(jì)應(yīng)采取地坪面保護(hù)措施。濟(jì)南ggd低壓抽屜柜一般使用柜體下部用圓木滾動(dòng)方式搬運(yùn)。濟(jì)南gcs開(kāi)關(guān)柜(源創(chuàng)開(kāi)關(guān)柜
)柜體就位應(yīng)按最里先進(jìn)的原則搬運(yùn)、吊裝。濟(jì)南gck開(kāi)關(guān)柜(五防開(kāi)關(guān)柜
)柜體搬運(yùn)到設(shè)置位置時(shí),濟(jì)南10kv高壓開(kāi)關(guān)柜(一體化開(kāi)關(guān)柜
)故障停電打開(kāi)包裝箱,濟(jì)南10kv高壓開(kāi)關(guān)柜(源創(chuàng)生產(chǎn)的開(kāi)關(guān)柜
)母線安裝方案檢查柜體方正、對(duì)角線、柜面平整等,濟(jì)南10kv高壓開(kāi)關(guān)柜(高低壓無(wú)線開(kāi)關(guān)柜
)主母線多大其誤差應(yīng)滿足表(3)要求。濟(jì)南10kv高壓開(kāi)關(guān)柜(可遠(yuǎn)程控制的開(kāi)關(guān)柜
)型號(hào)
表 ⑶ | 頂面 | 底部 | 左側(cè)面 | 右側(cè)面 | 前面 | 后面 |
對(duì)角誤差 | <1㎜ | <1㎜ | <2㎜ | <2㎜ | <2㎜ | <2㎜ |
平整度 | <1㎜ | <1㎜ | <1㎜ | <2㎜ | - | - |
柜體檢查合格后,濟(jì)南10kv高壓開(kāi)關(guān)柜(山東開(kāi)關(guān)柜
)原理圖將手車(chē)從柜體中拉出,濟(jì)南35kv高壓開(kāi)關(guān)柜(濰坊開(kāi)關(guān)柜
)型號(hào)柜體就位,濟(jì)南35kv高壓開(kāi)關(guān)柜(上海開(kāi)關(guān)柜
)尺寸柜體間用鍍鋅螺栓電氣連接。濟(jì)南10kv高壓開(kāi)關(guān)柜(高壓開(kāi)關(guān)柜
)結(jié)構(gòu)為保證柜面美觀,濟(jì)南35kv高壓開(kāi)關(guān)柜(高低壓開(kāi)關(guān)柜
)的額定電壓是多少一般采用柜體側(cè)面底部與基礎(chǔ)型鋼點(diǎn)焊,濟(jì)南35kv高壓開(kāi)關(guān)柜(開(kāi)關(guān)柜
)母線注意:每點(diǎn)焊粒不要太大,濟(jì)南35kv高壓開(kāi)關(guān)柜(帶智能操控裝置開(kāi)關(guān)柜
)多少錢(qián)一般直徑<4mm,濟(jì)南35kv高壓開(kāi)關(guān)柜(告知型號(hào)的開(kāi)關(guān)柜
)結(jié)構(gòu)圖否則將影響相鄰柜體的就位。濟(jì)南10kv高壓開(kāi)關(guān)柜(抽屜式開(kāi)關(guān)柜
)柜后放電對(duì)于雙列布置柜體就位時(shí),濟(jì)南35kv高壓開(kāi)關(guān)柜(35KV高壓開(kāi)關(guān)柜
)手車(chē)長(zhǎng)度應(yīng)注意母線橋的安裝位置及柜體與母線橋的連接對(duì)應(yīng)。濟(jì)南10kv高壓開(kāi)關(guān)柜(10KV高壓開(kāi)關(guān)柜
)故障柜體就位誤差應(yīng)滿足表(4)要求。濟(jì)南10kv高壓開(kāi)關(guān)柜(帶無(wú)線測(cè)溫開(kāi)關(guān)柜
)設(shè)計(jì)
表⑷ 垂直度(每米) 水平偏差 柜面偏差 柜間接縫
相鄰兩柜頂 成列柜頂全長(zhǎng) 相鄰兩柜邊 成列柜面全部
允許偏差(mm) <1.5 <2 <5 <1 <5 <2